Automatic Biomass
Boilers 
SMART 60 kWkotel_60-100kw_EN

 

  

 

 

 

 

 

 

 

• Fully automatic, ecologic boilers with excellent features • Technical solution flexibility • Multiple fuel possibility • Economical and ecological operation • 3 boilers in range • Efficiency 90 % • Output modulation 30–100 % • Lambda sensor • Stainless Steel Burner with Cleaning Mechanism • Low Maintenance & Service requirements • Heating circuits regulation • Cascade installation solutions • Mobile phone control • Internet control • Mobile container solutions • Special boiler accessories

SMART Boilers Application Options:

Extensive Houses

And Smaller-Scale:

Apartment Buildings
Multifunctional Buildings
Sports Complexes
Production Plants & Industrial Premises & Storage Premises
Agriculture & Aquaculture & Horticulture Farms
Hotels/Motels/Wellness Centres/Pools/Sport Arenas
Municipality Buildings
Schools, Hospitals, Police & Army Complexes

SMART BOILERS OPERATING DATA
Technical data of the boiler  
Marking   60
Nominal power Pn  kW 60
Partial load Pmin  kW 17
Boiler efficiency at Pn % 90
Boiler efficiency at Pmin % 89,1
Boiler class    5
Noise level dB < 65
Weight kg 783
Water  
Volume of water  l  129
Diameter of water connection  “ 2
Diameter of water connection DN 50
Hydraulic boiler loss attemperature gradient of 10° mbar 17
Hydraulic boiler loss attemperature gradient of 20° mbar  4,3
Boiler temperature °C  65–90°
Minimal temperature of returnable water °C 55
Maximal operational pressure bar 3,5
Test pressure bar 6
Hearth temperature °C  
Hearth pressure mbar -0,01
Required chimney draught mbar 0,2
Need for artificial draught   yes
Flue gas temperature at Pn °C 185
Mass flow rate of flue gas at Pn °C 90
Flue gas temperature at Pmin kg/h 180
Mass flow rate of flue gas at Pmin kg/h 60
Volume of flue gas at Pn m3/h 141
Volume of flue gas at Pmin m3/h 47
Smoke pipe diameter mm 200
Chimney diameter mm 200
Type of chimney   Moisture – resistant
Fuel    
Maximum size cm 3
Maximum moisture content % 30
Electric equipment
Connection    
Total W 3131
Ingress Protection Rating (IP)   41
 

Photo Gallery


[/column][/row]